HILARIS® TL with HAEMO

A HILARIS® TL therapeutic laser with an additional Haemo-Laser® set is used as a therapeutic device. The older ME-TL device series (from 50 mW) can also be retrofitted with a Haemo-Laser® set.

The Haemo-Laser® disposable light guide is coupled via the Haemo-Laser® patient adapter on the patient's forearm.

The Haemo-Laser® disposable light conductors are sterile single-use products for the simple and safe application of Haemo-Laser® therapy. The cannula that is already attached ensures the greatest possible safety and easy handling.

The fibre of the Haemo-Laser® disposable light conductor can also be introduced into a suitable intravenous cannula.

Integrated timer

Six selectable treatment times allow for comfortable and safe operation with HILARIS® TL. A short button press activates the laser beam after the time selection; continuous button actuation is no longer necessary.

Area irradiation without losses

For the treatment of large areas, HILARIS® TL emits the visible laser radiation without any losses whatsoever, as no intermediate adapters for beam expansion are required.

Ergonomic design

The HILARIS® TL combines the proven ease of use with the latest findings in ergonomics. This makes working with the HILARIS® TL a relaxed and safe treatment.

Lowest operating costs

Using standard batteries or rechargeable batteries in the HILARIS® TL saves you twice: long treatment times combined with lower battery prices keep operating costs low, and using rechargeable batteries increases treatment time even further and is also better for the environment.

Haemo-Laser® – Therapy

The HILARIS® TL is optimally usable with the Haemo-Laser® patient adapter for Haemo-Laser® – Therapy (intravascular laser blood irradiation).

Quality-controlled production

All devices are manufactured using the most modern production facilities and are tested according to the applicable standards. A comprehensive quality management system, which is regularly audited by the notified body, ensures constant control. Furthermore, an individual test protocol is created for each device, which contains all performance data.

This is how Haemo-Laser-Therapy works:

Technical data:*

Type

HILARIS® TL 50

HILARIS® TL 100

HILARIS® TL 150

HILARIS® TL 200

Output power

50 mW

100 mW

150 mW

200 mW

Wavelength

660 nm

660 nm

660 nm

660 nm

Operating time

up to 11 hours

up to 6 hours

up to 7 hours

up to 6 hours

Classification: Laser class 3B in accordance with EN 60825-1

The operating time refers to a set of batteries

* Subject to change!

We use cookies

We use cookies on our website. Some of them are essential for the operation of the site, while others help us to improve this site and the user experience (tracking cookies). You can decide for yourself whether you want to allow cookies or not. Please note that if you reject them, you may not be able to use all the functionalities of the site.